HPC7

Operated by Eni at Eni Green Data Center .

Phase 1 seed dataset, compiled by hand. These rows were built from public operator, laboratory and vendor sources. A mechanical second-reader pass has since fetched every cited source: 1092 of 1153 systems have a readable citation that names them, and 40 are genuinely weakly sourced. Every claim carries its source and a confidence tier. Treat anything below verified as a lead, not a citation.

Measured performance

Rmax
571.5 PFlop/s
HPL measured
Rpeak
861.1 PFlop/s
Rmax ÷ Rpeak
66.4%
Cores
3,461,472
Power
8.73 MW
Per watt
65.4 GF/W

Figures are as last publicly reported for the configuration described below, not a live measurement. Where a system was upgraded in place, the post-upgrade configuration is shown and the earlier one appears in the timeline.

What this machine is made of

One row per supplier relationship. “Supplier at build” is the company that shipped the part at the time; where that company has since been acquired, the parent it rolls up to today is shown beside it. That distinction is what makes ticker-level aggregation possible across a thirty-year dataset.

Role Part Supplier at build Quantity Confidence Source
Integrator -
HPE Cray EX255a
Hewlett Packard Enterprise - Verified eni.comtop500.org
Accelerator AMD Instinct MI300A
Accelerators
ROCm (CDNA 3) · TSMC N5/N6 · 550 W
AMD Instinct MI300A
AMD - Verified eni.comtop500.org
CPU AMD 4th Gen EPYC 24C (in MI300A)
CPUs
x86-64 · 24C · 1.8 GHz · TSMC N5
AMD 4th Gen EPYC 24C 1.8GHz (integrated in MI300A)
AMD - Verified eni.comtop500.org
Interconnect HPE Slingshot-11
Interconnect
Dragonfly · 200 Gb/s per port · Around 2 microseconds
Slingshot-11
Hewlett Packard Enterprise - Verified eni.comtop500.org
Storage HPE Cray ClusterStor E2000
Storage
HPE Cray ClusterStor E2000
Hewlett Packard Enterprise - Reported eni.com
Cooling Direct liquid cooling, warm water
Cooling
Direct-to-chip cold plates, facility water loop · Removes 90+ percent of node heat to liquid
innovative liquid cooling system, direct liquid cooling dissipating 96% of heat
Hewlett Packard Enterprise - Reported eni.comdecode39.com
Operating system Red Hat Enterprise Linux
Operating systems
Linux distribution · Open source, commercial support subscription
RHEL 9
Red Hat
IBMNYSE rolls up to IBM
- Reported top500.org

The read

HPC7 shares El Capitan's exact node design, the MI300A APU pairing a 24-core Zen 4 CPU with CDNA 3 GPU chiplets on unified HBM3: two systems built around the same silicon six months apart, one a US stockpile-stewardship machine and the other a European energy company's seismic-imaging cluster. Eni's own release states HPC7 does not replace HPC6, and the pair's combined Rmax already clears an exaflop between them. Eni's own page names artificial intelligence and molecular modeling alongside the oil-and-gas workloads HPC6 already carries, which is why this row is tagged mixed rather than hpc; no independent source has corroborated the AI-use claim specifically.

Timeline

Public list appearances

Pointers only: rank and edition, linking to the canonical entry. We do not reproduce list tables. See sourcing policy.

Site & facility

Eni Green Data Center

Location
Ferrera Erbognone, Italy

Change history

Source check

We fetched this system's own citations and recorded whether each page actually mentions it. This is a corroboration signal, not a fact check, and it is published so you can see how well the sourcing holds up rather than take it on trust.

Cited sourceResultFound on the page
top500.orgnames system and partAMD Instinct MI300A, HPE Slingshot-11, HPE Cray ClusterStor E2000
eni.comnames system and partAMD Instinct MI300A, Direct liquid cooling, warm water, HPE Cray ClusterStor E2000

Checked 2026-10-09 by pnpm verify. Re-run it and the table changes with the web.

Further reading