Phase 1 seed dataset, compiled by hand. These rows were built from public operator, laboratory and vendor sources. A mechanical second-reader pass has since fetched every cited source: 32 of 52 systems have a readable citation that names them, and 4 are genuinely weakly sourced. Every claim carries its source and a confidence tier. Treat anything below verified as a lead, not a citation.
Measured performance
- Rmax
- 19.48 PFlop/s
- Rpeak
- 26.87 PFlop/s
- Rmax ÷ Rpeak
- 72.5%
- Cores
- 305,856
- Power
- -
- Per watt
- - GF/W
Figures are as last publicly reported for the configuration described below, not a live measurement. Where a system was upgraded in place, the post-upgrade configuration is shown and the earlier one appears in the timeline.
What this machine is made of
One row per supplier relationship. “Supplier at build” is the company that shipped the part at the time; where that company has since been acquired, the parent it rolls up to today is shown beside it. That distinction is what makes ticker-level aggregation possible across a thirty-year dataset.
| Role | Part | Supplier at build | Quantity | Confidence | Source |
|---|---|---|---|---|---|
| Integrator | - Lenovo ThinkSystem SD650 | Lenovo | - | Reported | doku.lrz.de |
| CPU | Intel Xeon Platinum 8174 CPUs Xeon Platinum 8174 24C 3.1GHz | Intel | - | Reported | doku.lrz.de |
| Interconnect | Omni-Path Architecture Interconnect Intel Omni-Path | Intel | - | Reported | doku.lrz.de |
| Storage | IBM Spectrum Scale ESS (GPFS) Storage IBM Spectrum Scale | IBM | - | Reported | doku.lrz.de |
| Cooling | Direct liquid cooling, warm water Cooling Lenovo Neptune direct warm-water cooling | Lenovo | - | Reported | doku.lrz.de |
| Operating system | SUSE Linux Enterprise Server Operating systems SUSE Linux Enterprise Server | SUSE | - | Reported | doku.lrz.de |
The read
One of the largest Lenovo-integrated systems anywhere, and a reminder that Lenovo's position in this market came from a single 2014 transaction: IBM's x86 server business. Warm-water cooled with heat recovery, on Intel Omni-Path - a fabric its own vendor discontinued the year after this machine entered service.
Timeline
- 2017 Announced source
- 2018-09 First operational source
- 2018-11 List debut at #8 (November 2018) source
Public list appearances
Pointers only: rank and edition, linking to the canonical entry. We do not reproduce list tables. See sourcing policy.
Site & facility
Leibniz Supercomputing Centre, Garching
- Location
- Garching, Germany
- Cooling
- Direct warm-water cooling
- Commissioned
- 2006
Source check
We fetched this system's own citations and recorded whether each page actually mentions it. This is a corroboration signal, not a fact check, and it is published so you can see how well the sourcing holds up rather than take it on trust.
None of the cited sources could be read from our network: the hosts returned bot challenges or did not respond. This check says nothing about the citations either way. See how this check works.
| Cited source | Result | Found on the page |
|---|---|---|
| doku.lrz.de | blocked our fetch | - |
Checked 2026-09-08 by pnpm verify. Re-run it and the table changes with the web.
Further reading
Power and cooling
Why air ran out at 20 kW a rack, how warm-water cooling removes the chillers, and what PUE conceals.
Inside a node
Latency-optimised versus throughput-optimised processors, NUMA, and the end of the host-to-device copy.
Operating a supercomputer
Acceptance testing, why "installed" and "in production" are six months apart, and the machine lifecycle.