Researched with AI assistance, checked by scripts. These rows were researched by AI agents reading public operator, laboratory and vendor sources, appended by scripts and checked by automated validation; no subject-matter expert has reviewed them (how this site is made). A mechanical second-reader pass has since fetched every cited source: 1,350 of 1,581 systems have a readable citation that names them, and 64 are genuinely weakly sourced. Every claim carries its source and a confidence tier. Treat anything below verified as a lead, not a citation.
Measured performance
- Rmax
- 1.19 PFlop/s
- Rpeak
- 1.75 PFlop/s
- Rmax ÷ Rpeak
- 68.1%
- Cores
- 21,240
- Power
- 114.4 kW
- Per watt
- 10.4 GF/W
Figures are as last publicly reported for the configuration described below, not a live measurement. Where a system was upgraded in place, the post-upgrade configuration is shown and the earlier one appears in the timeline.
How it compares
Ranked against the other machines in this dataset that report the same figure: those that first came into service within two years of Wilkes-2, and those in United Kingdom. Computed from our tables; a metric is ranked only when at least eight peers report it.
| Metric | Value | Against its era | Against its country |
|---|---|---|---|
| Rmax | 1.19 PFlop/s | #141 of 234 · bottom 41% | #22 of 44 · top 49% |
| Energy efficiency | 10.4 GF/W | #17 of 158 · top 10% | #7 of 21 · top 30% |
| Rmax ÷ Rpeak | 68.1 % | #129 of 229 · bottom 45% | #30 of 44 · bottom 34% |
| Power draw | 114 kW | #143 of 161 · bottom 12% | #19 of 21 · bottom 11% |
Every metric is ranked largest-first, so a high power-draw rank means a big power draw, not a good one. Rmax ÷ Rpeak uses HPL-measured results only. Rankings move as machines are added; they describe this dataset, not the world.
What this machine is made of
One row per supplier relationship. “Supplier at build” is the company that shipped the part at the time; where that company has since been acquired, the parent it rolls up to today is shown beside it. That distinction is what makes ticker-level aggregation possible across a thirty-year dataset.
| Role | Part | Supplier at build | Quantity | Confidence | Source |
|---|---|---|---|---|---|
| Integrator | - Dell C4130 | Dell Technologies | - | Verified | top500.orgprnewswire.com |
| Accelerator | NVIDIA Tesla P100 Accelerators CUDA (Pascal GP100) · 3,584C · 1.48 GHz · 16 nm · 300 W NVIDIA Tesla P100 | NVIDIA | - | Reported | top500.org |
| CPU | Intel Xeon E5-2650 v4 CPUs x86-64 · 12C · 2.2 GHz · 14 nm Xeon E5-2650v4 12C 2.2GHz | Intel | - | Reported | top500.org |
| Interconnect | Mellanox InfiniBand EDR Interconnect Fat tree · 100 Gb/s per 4x port · About 0.9 microseconds Infiniband EDR | Mellanox NVDANASDAQ
rolls up to NVIDIA | - | Reported | top500.org |
Engineering, funding and access
What Wilkes-2 runs on, who paid for it and how people get time on it. Each line carries who said it and when.
Hardware
| Item | Detail | As of | Basis | Source |
|---|---|---|---|---|
| Compute nodes | 90 nodesDell PowerEdge C4130 nodes, each with one Xeon E5-2650 v4 (12 cores) and four NVIDIA Tesla P100-PCIE-16GB, 360 GPUs in total | 2019-10 | Operator stated | help.uis.cam.ac.uk |
| Interconnect and topology | Mellanox EDR InfiniBand, 100 Gbit/s | 2019-10 | Operator stated | help.uis.cam.ac.uktop500.org |
Software
| Item | Detail | As of | Basis | Source |
|---|---|---|---|---|
| Programming and software stack | HPL run on Scientific Linux with GNU and NVCC compilers, Intel MKL 11.3.3.210 and OpenMPI 1.10.2TOP500 list entry | 2017-06 | Operator stated | top500.org |
Funding
| Item | Detail | As of | Basis | Source |
|---|---|---|---|---|
| Funded by | University of Cambridge, co-investor in the 9 million pound CSD3 service that included Wilkes2 | 2019-10 | Operator stated | help.uis.cam.ac.uk |
| Funded by | Science and Technology Facilities Council (STFC), co-investor in the 9 million pound CSD3 service that included Wilkes2 | 2019-10 | Operator stated | help.uis.cam.ac.uk |
| Funded by | Engineering and Physical Sciences Research Council (EPSRC), co-investor in the 9 million pound CSD3 service that included Wilkes2 | 2019-10 | Operator stated | help.uis.cam.ac.uk |
| Funding programme | EPSRC Tier 2 National HPC Service (CSD3)CSD3 went live in November 2017; the 2019 slides list Wilkes2 as its P100 GPU platform | 2026 | Operator stated | docs.hpc.cam.ac.ukhelp.uis.cam.ac.uk |
| Procurement | Co-designed with Dell EMC, Intel and NVIDIA as part of CSD3; Dell EMC called the new Cambridge Research Computing Service system, including Wilkes-2, a USD 12M system in June 2017The University slides give a 9 million pound co-investment for CSD3 | 2017-06-20 | Vendor stated | prnewswire.comhelp.uis.cam.ac.uk |
The read
Cambridge's GPU successor to the original 2013 Wilkes cluster: Dell C4130 nodes, each two Xeon E5-2650v4 CPUs plus NVIDIA Tesla P100 accelerators, on InfiniBand EDR. Dell EMC's own ISC 2017 announcement independently confirms TOP500's ranking context, describing it as the largest GPU system in the UK, part of a $12M investment, ranked 100th on that TOP500 list and 5th on Green500; both TOP500's June 2017 Green500 list and Dell EMC's release independently agree on the 5th-place Green500 rank. Exact Rmax, Rpeak and core count rest on TOP500 alone, so the tier is reported. Cambridge's user guide (https://docs.hpc.cam.ac.uk/hpc/user-guide/upgrade2021.html) scheduled Wilkes-2's final retirement for 28 February 2022.
Timeline
- 2017 Announced source
- 2017 First operational source
- 2017-06 Listed at #101 on the TOP500 (June 2017) source
- 2021-11-10 Half of the Wilkes2 P100 GPU nodes left production service after the A100 Ampere racks entered production source
- 2022-02-28 Cambridge scheduled the final retirement of the Wilkes2 P100 GPU service for 28 February 2022 source
Public list appearances
Pointers only: rank and edition, linking to the canonical entry. We do not reproduce list tables. See sourcing policy.
Site & facility
University of Cambridge (CSD3)
- Location
- Cambridge, United Kingdom
- Commissioned
- 2024
Change history
- 2026-11-08 Wilkes-2 marked decommissioned
- 2026-09-24 Wilkes-2 added
Nearby in scale
The machines closest to Wilkes-2 by Rmax, smaller to larger.
- TSUBAME2.0 · Japan, upgraded · 1.19 PFlop/s
- Sekirei (ISSP System B) · Japan, decommissioned · 1.18 PFlop/s
- Garnet · USA, operational · 1.17 PFlop/s
- Roshydromet Cray XC40 · Russia, operational · 1.2 PFlop/s
- Blue Joule · United Kingdom, decommissioned · 1.21 PFlop/s
- RAIDEN · Japan, operational · 1.21 PFlop/s
Related systems
Same site
- Peta4 · United Kingdom, upgraded, 2017
- Cumulus Cascade Lake · United Kingdom, operational, 2020
- Wilkes-3 · United Kingdom, operational, 2021
- Dawn · United Kingdom, operational, 2024
- Zenith · United Kingdom, operational, 2026
Same operator
- Cumulus (Cambridge) · United Kingdom, operational, 2018
- Wilkes · United Kingdom, decommissioned, 2013
- Darwin III · United Kingdom, decommissioned, 2012
- Cambridge Hitachi SR2201/96 · United Kingdom, operational, 1996
Same accelerator
- AIST AI Cloud · Japan, operational, 2017
- Cedar (SFU) · Canada, decommissioned, 2017
- CNIC Era-AI · China, operational, 2017
- Facebook DGX-1 Cluster · USA, operational, 2017
- Graham · Canada, decommissioned, 2017
- Kukai · Japan, operational, 2017
Source check
We fetched this system's own citations and recorded whether each page actually mentions it. This is a corroboration signal, not a fact check, and it is published so you can see how well the sourcing holds up rather than take it on trust.
| Cited source | Result | Found on the page |
|---|---|---|
| top500.org | names system and part | NVIDIA Tesla P100, Intel Xeon E5-2650 v4, Mellanox InfiniBand EDR |
| prnewswire.com | names system and part | Intel Xeon E5-2650 v4 |
Checked 2026-10-18 by pnpm verify. Re-run it and the table changes with the web.
Further reading
Inside a node
Why accelerators exist, what the memory hierarchy costs, and how the CPU and accelerator merged onto one package.
The interconnect
Topologies, why latency and tail behaviour matter more than bandwidth, and how the fabric market consolidated.
Operating a supercomputer
Acceptance testing, why "installed" and "in production" are six months apart, and the machine lifecycle.