Supercomputers/Systems/Roihu

Finland · operational · mixed

Roihu

Operated by CSC at LUMI Data Center, Kajaani .

Phase 1 seed dataset, compiled by hand. These rows were built from public operator, laboratory and vendor sources. A mechanical second-reader pass has since fetched every cited source: 1092 of 1153 systems have a readable citation that names them, and 40 are genuinely weakly sourced. Every claim carries its source and a confidence tier. Treat anything below verified as a lead, not a citation.

Measured performance

Rmax
-
Rpeak
-
Rmax ÷ Rpeak
-
Cores
-
Power
-
Per watt
- GF/W

Figures are as last publicly reported for the configuration described below, not a live measurement. Where a system was upgraded in place, the post-upgrade configuration is shown and the earlier one appears in the timeline.

What this machine is made of

One row per supplier relationship. “Supplier at build” is the company that shipped the part at the time; where that company has since been acquired, the parent it rolls up to today is shown beside it. That distinction is what makes ticker-level aggregation possible across a thirty-year dataset.

Role Part Supplier at build Quantity Confidence Source
Integrator -
BullSequana XH3000 hybrid system, liquid-cooled
Bull
ATOEPA rolls up to Atos
- Reported csc.fibull.com
Accelerator NVIDIA GH200 Grace Hopper Superchip
Accelerators
Arm CPU + CUDA GPU · TSMC 4N
132 GPU nodes with four NVIDIA GH200 superchips each
NVIDIA 528
reported
Reported csc.fi
CPU AMD EPYC 9005 (Turin)
CPUs
x86-64 · 192C · 2.7 GHz · TSMC N3E · 500 W
486 CPU nodes, two 192-core AMD EPYC Turin 9965 each
AMD - Reported csc.fi

The read

Finland's new national supercomputer, a liquid-cooled Bull BullSequana XH3000 hybrid system in CSC's Kajaani data centre alongside LUMI, replacing Puhti and Mahti. CSC lists 486 CPU nodes with two 192-core AMD EPYC Turin 9965 CPUs each and 132 GPU nodes with four NVIDIA GH200 superchips each, a 6.0 PiB flash scratch file system and a 0.5 PiB project and home system. Pilot use began in April 2026, the system was inaugurated in May 2026 and became generally available on 29 June 2026. CSC states only estimated HPL of above 10 PFlop/s for the CPU nodes and above 20 PFlop/s for the GPU nodes, and different CSC and press pages quote different combined theoretical peaks (33.9 and 49 PFlop/s), so no FLOPS figure is recorded. Bull's own press release confirms the delivery, the Kajaani location and the liquid-cooled BullSequana platform but not the node counts; it has no TOP500 entry that was confirmed.

Timeline

Site & facility

LUMI Data Center, Kajaani

Location
Kajaani, Finland
Cooling
Direct liquid cooling with waste-heat recovery
PUE
1.03
Commissioned
2022

Change history

Source check

We fetched this system's own citations and recorded whether each page actually mentions it. This is a corroboration signal, not a fact check, and it is published so you can see how well the sourcing holds up rather than take it on trust.

Cited sourceResultFound on the page
csc.finames system and partNVIDIA GH200 Grace Hopper Superchip
bull.comnames system only-

Checked 2026-10-09 by pnpm verify. Re-run it and the table changes with the web.

Further reading