Supercomputers/Systems/Wind River
USA · operational · hpc
Wind River
Also known as WindRiver CTS-2
Operated by INL .
Researched with AI assistance, checked by scripts. These rows were researched by AI agents reading public operator, laboratory and vendor sources, appended by scripts and checked by automated validation; no subject-matter expert has reviewed them (how this site is made). A mechanical second-reader pass has since fetched every cited source: 1,350 of 1,581 systems have a readable citation that names them, and 64 are genuinely weakly sourced. Every claim carries its source and a confidence tier. Treat anything below verified as a lead, not a citation.
Measured performance
- Rmax
- 5.33 PFlop/s
- Rpeak
- 6.04 PFlop/s
- Rmax ÷ Rpeak
- 88.2%
- Cores
- 94,416
- Power
- 893.4 kW
- Per watt
- 6.0 GF/W
Figures are as last publicly reported for the configuration described below, not a live measurement. Where a system was upgraded in place, the post-upgrade configuration is shown and the earlier one appears in the timeline.
How it compares
Ranked against the other machines in this dataset that report the same figure: those that first came into service within two years of Wind River, and those in USA. Computed from our tables; a metric is ranked only when at least eight peers report it.
| Metric | Value | Against its era | Against its country |
|---|---|---|---|
| Rmax | 5.33 PFlop/s | - | #78 of 332 · top 23% |
| Energy efficiency | 6.0 GF/W | - | #40 of 162 · top 24% |
| Rmax ÷ Rpeak | 88.2 % | - | #32 of 331 · top 9% |
| Power draw | 893 kW | - | #67 of 171 · top 39% |
Every metric is ranked largest-first, so a high power-draw rank means a big power draw, not a good one. Rmax ÷ Rpeak uses HPL-measured results only. Rankings move as machines are added; they describe this dataset, not the world.
What this machine is made of
One row per supplier relationship. “Supplier at build” is the company that shipped the part at the time; where that company has since been acquired, the parent it rolls up to today is shown beside it. That distinction is what makes ticker-level aggregation possible across a thirty-year dataset.
| Role | Part | Supplier at build | Quantity | Confidence | Source |
|---|---|---|---|---|---|
| Integrator | - Dell PowerEdge CTS-2 system, 843 nodes in 20 racks | Dell Technologies | - | Reported | top500.orginl.gov |
| CPU | - Intel Xeon Platinum 8480+ 56C 2GHz | Intel | - | Reported | top500.org |
| Interconnect | Omni-Path Architecture Interconnect Fat tree · 100 Gb/s per port · About 1 microsecond Omni-Path (OPA) interconnect | Cornelis Networks | - | Verified | inl.govtop500.org |
| Operating system | Rocky Linux Operating systems RHEL-compatible Linux, community-maintained · Downstream rebuild of Red Hat Enterprise Linux source Rocky Linux 8 | Rocky Enterprise Software Foundation | - | Reported | top500.org |
Engineering, funding and access
What Wind River runs on, who paid for it and how people get time on it. Each line carries who said it and when.
Hardware
| Item | Detail | As of | Basis | Source |
|---|---|---|---|---|
| Interconnect and topology | Intel Omni-PathTOP500 submission for the Dell CTS-2 system. | 2026-06 | Operator stated | top500.org |
Software
| Item | Detail | As of | Basis | Source |
|---|---|---|---|---|
| Programming and software stack | Rocky Linux 8 operating system | 2026-06 | Operator stated | top500.org |
| Programming and software stack | Intel oneAPI DPC++/C++ Compiler 2024.2 and Intel MPI 2021.13Toolchain listed for the HPL run. | 2026-06 | Operator stated | top500.org |
The read
Idaho National Laboratory's Wind River supercomputer, named for the Wind River Range in Wyoming and a CTS-2 class machine. INL's HPC page lists it as arrived in 2024 with 20 racks, 843 nodes, 94,416 cores, 5.3 PFLOPS and an Omni-Path (OPA) interconnect. TOP500 lists WindRiver CTS-2 as a Dell PowerEdge (CTS-2) system with Xeon Platinum 8480+ 56C 2GHz hosts on Intel Omni-Path under Rocky Linux 8, installed 2025, with the same 94,416 cores, Rmax 5.33 PFlop/s, Rpeak 6.04 PFlop/s and 893.4 kW (level 1); it debuted at rank 234 on the June 2025 list and was 291st in June 2026. The two sources agree on cores, performance and interconnect, so the tier is verified. INL gives the arrival year 2024 and TOP500 the install year 2025, so no in-service date is recorded, and INL's page lists a total memory figure that was not used. The campus is not stated, so the site is left blank.
Timeline
- 2025-06 Listed at #234 on the TOP500 (June 2025) source
Public list appearances
Pointers only: rank and edition, linking to the canonical entry. We do not reproduce list tables. See sourcing policy.
Change history
- 2026-10-07 Added Wind River (inl)
Nearby in scale
The machines closest to Wind River by Rmax, smaller to larger.
- Pangea II · France, upgraded · 5.28 PFlop/s
- Berzelius · Sweden, operational · 5.25 PFlop/s
- CLAIX-2023 · Germany, operational · 5.24 PFlop/s
- Mahti · Finland, decommissioned · 5.39 PFlop/s
- Clementina XXI · Argentina, operational · 5.39 PFlop/s
- Snellius (Phase 2 CPU) · Netherlands, operational · 5.4 PFlop/s
Related systems
Same operator
- Ice Storm · USA, operational, 2007
- Fission (INL) · USA, operational, 2011
- INL Falcon · USA, decommissioned, 2014
- Lemhi · USA, decommissioned, 2018
- Sawtooth · USA, operational, 2019
- Teton · USA, operational, 2026
Source check
We fetched this system's own citations and recorded whether each page actually mentions it. This is a corroboration signal, not a fact check, and it is published so you can see how well the sourcing holds up rather than take it on trust.
| Cited source | Result | Found on the page |
|---|---|---|
| inl.gov | could not be fetched | - |
| top500.org | names system and part | Omni-Path Architecture, Rocky Linux |
Checked 2026-10-18 by pnpm verify. Re-run it and the table changes with the web.
Further reading
Operating a supercomputer
Acceptance testing, why "installed" and "in production" are six months apart, and the machine lifecycle.
Inside a node
Latency-optimised versus throughput-optimised processors, NUMA, and the end of the host-to-device copy.
The interconnect
Topologies, why latency and tail behaviour matter more than bandwidth, and how the fabric market consolidated.