Supercomputers/Systems/PARAM Rudra (IUAC)

India · operational · mixed

PARAM Rudra (IUAC)

Also known as PARAM Rudra Delhi; IUAC PARAM Rudra

Operated by IUAC at IUAC Delhi Campus .

Researched with AI assistance, checked by scripts. These rows were researched by AI agents reading public operator, laboratory and vendor sources, appended by scripts and checked by automated validation; no subject-matter expert has reviewed them (how this site is made). A mechanical second-reader pass has since fetched every cited source: 1,350 of 1,581 systems have a readable citation that names them, and 64 are genuinely weakly sourced. Every claim carries its source and a confidence tier. Treat anything below verified as a lead, not a citation.

Measured performance

Rmax
-
operator stated
Rpeak
3.00 PFlop/s
Rmax ÷ Rpeak
-
Cores
-
Power
-
Per watt
- GF/W

Figures are as last publicly reported for the configuration described below, not a live measurement. Where a system was upgraded in place, the post-upgrade configuration is shown and the earlier one appears in the timeline.

What this machine is made of

One row per supplier relationship. “Supplier at build” is the company that shipped the part at the time; where that company has since been acquired, the parent it rolls up to today is shown beside it. That distinction is what makes ticker-level aggregation possible across a thirty-year dataset.

Role Part Supplier at build Quantity Confidence Source
Integrator -
650 RUDRA-based compute nodes designed and commissioned by C-DAC; servers supplied by VVDN Technologies
C-DAC
650
reported
Reported cdac.in

Engineering, funding and access

What PARAM Rudra (IUAC) runs on, who paid for it and how people get time on it. Each line carries who said it and when.

Hardware

ItemDetailAs ofBasisSource
Compute nodes650 nodesRUDRA-based compute nodes, per C-DAC2024-09Vendor statedcdac.in
Cooling designLiquid cooling, described by C-DAC as energy efficient and lowering the data centre carbon footprint2024-09Vendor statedcdac.in

Software

ItemDetailAs ofBasisSource
Programming and software stackC-DAC's in-house HPC software stack built on open-source tools2024-09Vendor statedcdac.in

Funding

ItemDetailAs ofBasisSource
Funding programmeNational Supercomputing Mission (NSM) Phase 3, a joint MeitY and DST initiative2024-09Vendor statedcdac.in
ProcurementC-DAC-designed Rudra servers manufactured by VVDN Technologies of Gurgaon under C-DAC technology transferC-DAC also transferred the Rudra technology to Kaynes Technology and Avalon Technologies2024-09Vendor statedcdac.in

The read

One of three PARAM Rudra facilities dedicated on 27 September 2024 under National Supercomputing Mission phase 3, alongside installations at GMRT Pune (1 PFlop, GPU in all nodes) and SNBNCBS Kolkata (838 TFlops). C-DAC's release gives the IUAC machine a peak of 3 PetaFlops on 650 RUDRA-based compute nodes with energy-efficient liquid cooling; it names VVDN Technologies of Gurgaon as the server supplier for the inaugurated facilities and does not give CPU, GPU or interconnect specifications.

Timeline

Site & facility

IUAC Delhi Campus

Location
New Delhi, India
Cooling
Liquid cooling
Commissioned
2024

Change history

Source check

We fetched this system's own citations and recorded whether each page actually mentions it. This is a corroboration signal, not a fact check, and it is published so you can see how well the sourcing holds up rather than take it on trust.

None of the cited sources could be read from our network: the hosts returned bot challenges or did not respond. This check says nothing about the citations either way. See how this check works.

Cited sourceResultFound on the page
cdac.incould not be fetched-

Checked 2026-10-18 by pnpm verify. Re-run it and the table changes with the web.

Further reading