COMPUTE ATLAS Supercomputer supply-chain graph
1581 systems 558 sites Sourced data

Supercomputers/Systems/MAXIMUS-384

USA · operational · ai training

MAXIMUS-384

Also known as Maximus-01

Operated by Core42 at Core42 (Lake Mariner) .

Researched with AI assistance, checked by scripts. These rows were researched by AI agents reading public operator, laboratory and vendor sources, appended by scripts and checked by automated validation; no subject-matter expert has reviewed them (how this site is made). A mechanical second-reader pass has since fetched every cited source: 1,350 of 1,581 systems have a readable citation that names them, and 64 are genuinely weakly sourced. Every claim carries its source and a confidence tier. Treat anything below verified as a lead, not a citation.

Measured performance

Rmax
114.5 PFlop/s
HPL measured
Rpeak
251.2 PFlop/s
Rmax ÷ Rpeak
45.6%
Cores
976,896
Power
-
Per watt
- GF/W

Figures are as last publicly reported for the configuration described below, not a live measurement. Where a system was upgraded in place, the post-upgrade configuration is shown and the earlier one appears in the timeline.

How it compares

Ranked against the other machines in this dataset that report the same figure: those that first came into service within two years of MAXIMUS-384, and those in USA. Computed from our tables; a metric is ranked only when at least eight peers report it.

MetricValueAgainst its eraAgainst its country
Rmax114.5 PFlop/s#20 of 202 · top 9%#10 of 332 · top 3%
Rmax ÷ Rpeak45.6 %#194 of 199 · bottom 4%#322 of 331 · bottom 4%

Every metric is ranked largest-first, so a high power-draw rank means a big power draw, not a good one. Rmax ÷ Rpeak uses HPL-measured results only. Rankings move as machines are added; they describe this dataset, not the world.

What this machine is made of

One row per supplier relationship. “Supplier at build” is the company that shipped the part at the time; where that company has since been acquired, the parent it rolls up to today is shown beside it. That distinction is what makes ticker-level aggregation possible across a thirty-year dataset.

Role Part Supplier at build Quantity Confidence Source
Integrator -
Dell PowerEdge XE9680
Dell Technologies - Reported top500.org
Accelerator AMD Instinct MI300X
Accelerators
ROCm (CDNA 3) · TSMC N5/N6 · 750 W
>9,000 AMD Instinct MI300X GPUs
AMD - Verified top500.orgcore42.ai
CPU Intel Xeon Platinum 8570
CPUs
x86-64 · 56C · 2.1 GHz · Intel 7
Xeon Platinum 8570 56C
Intel - Reported top500.org
Interconnect Broadcom RoCE Ethernet
Interconnect
RoCE over Broadcom silicon, Arista Networks EOS switches
Broadcom - Verified top500.orgcore42.ai

Engineering, funding and access

What MAXIMUS-384 runs on, who paid for it and how people get time on it. Each line carries who said it and when.

Hardware

ItemDetailAs ofBasisSource
Interconnect and topologyRoCE Ethernet: Broadcom networking chips with Arista Ethernet switches running EOSTOP500 entry lists RoCE.2025-11Operator statedcore42.aitop500.org

Software

ItemDetailAs ofBasisSource
Programming and software stackUbuntu 22.04.3 LTS, HIPCC and Open MPI (as submitted for the TOP500 HPL run)2025-11Operator statedtop500.org

Access

ItemDetailAs ofBasisSource
How researchers get timeDelivered globally through the Core42 AI Cloud with unified orchestration, enterprise-grade security and data-management controls2025-11Operator statedcore42.ai

Results

ItemDetailAs ofBasisSource
Notable result2025: ranked 20th on the November 2025 TOP500 at 114.50 PFlop/s RmaxCore42 reports more than 9,000 AMD Instinct MI300X GPUs.2025-11Operator statedcore42.aitop500.org

AI datacenter metrics

Figures beyond an accelerator count, each with who stated it. What can and cannot be compared across AI datacenters.

MetricValueAs ofBasisNoteSource
Accelerators 9,000 accelerators 2025-11 Operator stated Core42 release (18 Nov 2025): more than 9,000 AMD MI300X GPUs at Lake Mariner, Buffalo (value is the floor). core42.ai

The read

Core42's own branding calls this cluster Maximus-01; TOP500 and wire-service headlines both also use MAXIMUS-384, so both names are recorded. Over 9,000 AMD Instinct MI300X GPUs at TeraWulf's Lake Mariner data center campus, networked on Broadcom silicon and Arista switches. The press release is widely syndicated but traces to one source, so this stays at reported rather than verified tier.

Timeline

  • 2025-11 Announced source
  • 2025-11 First operational source
  • 2025-11-22 Core42 renamed Maximus-384 as Maximus-01 in its own branding source
  • 2026-06 Listed at #24 on the TOP500 (June 2026) source

Public list appearances

Pointers only: rank and edition, linking to the canonical entry. We do not reproduce list tables. See sourcing policy.

Site & facility

Core42 (Lake Mariner)

Location
Buffalo, NY, USA
Commissioned
2025

Nearby in scale

The machines closest to MAXIMUS-384 by Rmax, smaller to larger.

  • SSC-24 · South Korea, operational · 106.2 PFlop/s
  • Venado · USA, operational · 98.51 PFlop/s
  • Sierra · USA, decommissioned · 94.64 PFlop/s
  • Eos · USA, operational · 121.4 PFlop/s
  • Shaheen III - GPU · Saudi Arabia, operational · 122.8 PFlop/s
  • CHIE-4 · Japan, operational · 135.4 PFlop/s

Same site

Same operator

  • AI-03 · United Arab Emirates, operational, 2025
  • SuperPOD · United Arab Emirates, operational, 2024

Same accelerator

Source check

We fetched this system's own citations and recorded whether each page actually mentions it. This is a corroboration signal, not a fact check, and it is published so you can see how well the sourcing holds up rather than take it on trust.

Cited sourceResultFound on the page
top500.orgnames system and partAMD Instinct MI300X, Intel Xeon Platinum 8570
core42.ainames system and partAMD Instinct MI300X, Broadcom RoCE Ethernet

Checked 2026-10-18 by pnpm verify. Re-run it and the table changes with the web.

Further reading