Supercomputers/Systems/Shell Houston HPC Cluster
USA · operational · hpc
Shell Houston HPC Cluster
Also known as Shell Skybox Houston One immersion-cooled AMD EPYC cluster
Operated by Shell at Shell Skybox Houston One Data Center .
Phase 1 seed dataset, compiled by hand. These rows were built from public operator, laboratory and vendor sources. A mechanical second-reader pass has since fetched every cited source: 1092 of 1153 systems have a readable citation that names them, and 40 are genuinely weakly sourced. Every claim carries its source and a confidence tier. Treat anything below verified as a lead, not a citation.
Measured performance
- Rmax
- -
- Rpeak
- -
- Rmax ÷ Rpeak
- -
- Cores
- 165,888
- Power
- 1.20 MW
- Per watt
- - GF/W
Figures are as last publicly reported for the configuration described below, not a live measurement. Where a system was upgraded in place, the post-upgrade configuration is shown and the earlier one appears in the timeline.
What this machine is made of
One row per supplier relationship. “Supplier at build” is the company that shipped the part at the time; where that company has since been acquired, the parent it rolls up to today is shown beside it. That distinction is what makes ticker-level aggregation possible across a thirty-year dataset.
| Role | Part | Supplier at build | Quantity | Confidence | Source |
|---|---|---|---|---|---|
| Integrator | - Penguin Solutions Altus dual-socket servers (864 systems) | Penguin Computing | 864 reported | Reported | penguinsolutions.comgrcooling.com |
| CPU | AMD EPYC 9004 (Genoa) CPUs x86-64 · 96C · 2.4 GHz · TSMC N5 · 360 W 1,728 x 4th Gen AMD EPYC 9654 (96-core), 165,888 cores across 864 dual-socket servers | AMD | 1,728 reported | Reported | penguinsolutions.com |
| Cooling | - 6 x GRC ICEraQ Series 10 Duo single-phase immersion cooling units (200 kW each) | GRC (Green Revolution Cooling) | 6 reported | Reported | penguinsolutions.comgrcooling.com |
The read
CPU-only HPC cluster run by Shell IT at the Skybox Houston One data center in Katy, Texas: 864 dual-socket Penguin Solutions Altus servers with 4th Gen AMD EPYC 9654 (96-core) processors, 1,728 CPUs and 165,888 cores, cooled by six GRC ICEraQ Series 10 Duo single-phase immersion units. GRC's customer page puts the installation at 1.2 MW of compute (200 kW per immersion unit), recorded here as power_kw. Shell's Houston data center is stated to run on 100 percent renewable power from Shell Energy North America. No installation date or FLOPS figure is published, so first_operational_date is blank and no Rpeak is recorded; status_as_of is the date of the Penguin Solutions write-up as syndicated by CIO. An AMD case study on the same deployment exists but could not be fetched, so it is not cited. Whether this hall is the same one used by DUG's Bubba at Skybox Houston (also Katy) is not stated by any source, so the site is recorded separately.
Timeline
No dated events recorded.
Site & facility
Shell Skybox Houston One Data Center
- Location
- Katy, TX, USA
- Utility
- Shell Energy North America
- Cooling
- Single-phase immersion cooling (GRC ICEraQ)
Change history
- 2026-10-01 Added Shell Houston HPC Cluster (Shell)
Source check
We fetched this system's own citations and recorded whether each page actually mentions it. This is a corroboration signal, not a fact check, and it is published so you can see how well the sourcing holds up rather than take it on trust.
| Cited source | Result | Found on the page |
|---|---|---|
| grcooling.com | names system only | - |
| penguinsolutions.com | names system, part and count | AMD EPYC 9004 (Genoa) · counts: 1728 |
Checked 2026-10-09 by pnpm verify. Re-run it and the table changes with the web.
Further reading
Operating a supercomputer
Acceptance testing, why "installed" and "in production" are six months apart, and the machine lifecycle.
Inside a node
Latency-optimised versus throughput-optimised processors, NUMA, and the end of the host-to-device copy.
Power and cooling
Why air ran out at 20 kW a rack, how warm-water cooling removes the chillers, and what PUE conceals.